ADILAH ROJAS, ZAHIRA (2024) PENGUKURAN KEBOCORAN RADIASI PADA RUANGAN KONVENSIONAL DI INSTALASI RADIOLOGI RSUD BANGKINANG. D3 Teknik Radiologi thesis, Universitas Awal Bros.
![]() |
Text
BAB1_ZAHIRA ADILAH ROJAS.docx Download (18kB) |
![]() |
Text
KTI Zahira Adilah Rojas 21002049.docx Download (3MB) |
![]() |
Text
DAFTAR PUSTAKA ZAHIRA ADILAH ROJAS.docx Download (18kB) |
Abstract
ABSTRAK Latar Belakang: Di Instalasi Radiologi Bangkinang telah dilakukan pengukuran kebocoran radiasi secara rutin. Terakhir dilakukan pengukuran kebocora radiasi pada tahun 2023. Akan tetapi, setelah dilakukan pengukuran pada waktu tertentu, penulis melakukan penelitian diketahui bahwa pintu utama pemeriksaan mengalami kerenggangan atau tidak tertutup dengan rapat. Tujuan dari penelitian ini untuk mengetahui hasil pengukuran kebocoran radiasi pada ruangan konvensional di Instalasi Radiologi RSUD Bangkinang Metode: Jenis penelitian ini adalah penelitian kuantitatif deskriptif dengan pendekatan observasi. Penelitian ini dilakukan pada Mei 2024. Pengambilan data dilakukan dengan cara obsevasi, pengukuran, dokumentasi dengan menggunakan alat surveymeter di 7 daerah. Analisis data dilakukan dengan cara membandingkan hasil pengukuran dengan ketentuan yang telah ditetapkan oleh Perka BAPETEN No. 15 Tahun 2014. Hasil: Hasil pengukuran dari titik yang telah ditentukan, diketahui bahwa nilai tertinggi adalah pada titik A sebesar 0,0003096 mSv/jam dan nilai terendah pada titik C sebesar 0 mSv/jam. Meskipun pada titik A memiliki nilai yang tertinggi tetapi masih kategori batas aman karena hasil pengukuran tidak melebihi NBD yang telah ditetapkan oleh Perka BAPETEN No. 15 Tahun 2014 yaitu 0,01 mSv/minggu untuk pekerja radiasi dan anggota masyarakat yaitu 0,001 mSv/jam. ABSTRACT Background: At the Bangkinang Radiology Installation, radiation leak measurements have been carried out routinely. The last radiation leak measurement was carried out in 2023. However, after measurements were carried out at a certain time, the author conducted research and it was discovered that the main inspection door was loose or not closed tightly. The aim of this research is to determine the results of measurements of radiation leaks in conventional rooms at the Radiology Installation at Bangkinang Hospital Method: This type of research is quantitative descriptive research with an observational approach. This research was conducted in May 2024. Data collection was carried out by observation, measurement, documentation using a surveymeter in 7 area. Data analysis is carried out by comparing the measurement results with the provisions stipulated by BAPETEN Perka No. 15 of 2014. Results: From the measurement results from the determined points, it is known that the highest value is at point A of 0.0003096 mSv/hour and the lowest value is at point C of 0 mSv/hour. Even though point A has the highest value, it is still in the safe limit category because the measurement results do not exceed the NBD set by BAPETEN Perka No. 15 of 2014, namely 0.01 mSv/week for radiation workers and members of the public, namely 0.001 mSv/hour.
Item Type: | Thesis (D3 Teknik Radiologi) |
---|---|
Subjects: | D3 Radiologi > X-Ray Konvensional |
Divisions: | Fakultas Ilmu Kesehatan > D3 Radiologi |
Depositing User: | Zahira Adilah Rojas |
Date Deposited: | 27 Feb 2025 02:45 |
Last Modified: | 27 Feb 2025 02:45 |
URI: | http://repository.univawalbros.ac.id/id/eprint/421 |