Sugesty, Salwa (2024) UJI KESESUAIAN BERKAS CAHAYA KOLIMATOR PADA PESAWAT X-RAY MOBILE DI INSTALASI RADIOLOGI RSAU dr. SUKIRMAN. D3 Teknik Radiologi thesis, Universitas Awal Bros.
![]() |
Text
KTI_SALWA INNASYA SUGESTY_21002042.pdf Download (2MB) |
![]() |
Text
BAB I SALWA INNASYA SUGESTY.pdf Download (122kB) |
![]() |
Text
DAFTAR PUSTAKA SALWA INNASYA SUGESTY (1).docx Download (15kB) |
Abstract
ABSTRAK Uji Kesesuaian adalah pengujian untuk memastikan bahwa pesawat Sinar-X memenuhi persyaratan keselamatan radiasi dan memberikan informasi diagnosis yang akurat. Salah satu uji yang dilakukan yaitu uji kesesuaian luas berkas cahaya kolimator dengan berkas sinar-X dan uji titik fokus. Di Instalasi Radiologi RSAU dr. Sukirman, alat X-Ray Mobile sering dipindahkan melalui jalan yang tidak datar yang memungkinkan terjadi pergeseran plat timbal atau cerminnya. Tujuannya untuk mengetahui hasil uji kesesuaian berkas cahaya kolimator dan titik fokus mengalami pergeseran akibat perpindahan melalui jalan yang tidak datar. Jenis penelitian yang digunakan yaitu metode kuantitatif deskriptif dengan pendekatan observasional. Pengambilan data menggunakan collimator test tool dan beam alignment. Uji kesesuaian ini menggunakan focal spot kecil dengan faktor eksposi 60 kV dan 8 mAs dan focal spot besar 60 Kv dan 16 mAs dengan menguji dua kali pada setiap focal spot. Berdasarkan hasil uji, diperoleh nilai rata-rata sumbu X yaitu 0,477 cm dan sumbu Y 1,141 cm untuk focal spot kecil, untuk focal spot besar diperoleh nilai rata-rata sumbu X 0,644 cm dan sumbu Y 1,372 cm. Untuk uji ketepatan titik fokus pada empat kali percobaan tidak ada penyimpangan titik pusat yang melebihi batas toleransi.Kesimpulannya yaitu kolimator pada pesawat X-Ray Mobile di Instalasi Radiologi RSAU dr Sukirman masih layak digunakan karena masih dalam batas toleransi yang telah ditetapkan yaitu ≤ 2% dari FFD. Kata Kunci : Uji Kesesuaian, Collimator Test Tool, Beam Alignment ABSTRACT Compliance Testing is testing to ensure that the X-Ray aircraft meets radiation safety requirements and provides accurate diagnostic information. One of the tests carried out is the compatibility test of the area of the collimator light beam with the X-ray beam. At the RSAU Radiology Installation, Dr. Sukirman, Mobile X-Ray equipment is often moved along uneven roads which can cause the lead plate or mirror to shift. The aim is to find out the results of the suitability test of the collimator light beam and the focal point experiencing shifts due to movement over uneven roads. The type of research used is a descriptive quantitative method with an observational approach. Data collection uses a collimator test tool and beam alignment. This suitability test uses a small focal spot with an exposure factor of 60 kV and 8 mAs and a large focal spot of 60 Kv and 16 mAs by testing twice on each focal spot. Based on the test results, the average value for the X axis was 0.477 cm and the Y axis was 1.141 cm for the small focal spot, for the large focal spot the average value for the X axis was 0.644 cm and the Y axis was 1.372 cm. For the focus point accuracy test, in four trials there was no center point deviation that exceeded the tolerance limit. The conclusion is that the collimator on the Mobile X-Ray aircraft at the RSAU Dr Sukirman Radiology Installation is still suitable for use because it is still within the predetermined tolerance limit, namely ≤ 2% of FFD. Keywords: Conformity Test, Collimator Test Tool, Beam Alignment
Item Type: | Thesis (D3 Teknik Radiologi) |
---|---|
Subjects: | D3 Radiologi > X-Ray Konvensional |
Divisions: | Fakultas Ilmu Kesehatan > D3 Radiologi |
Depositing User: | Salwa Innasya Sugesty |
Date Deposited: | 27 Feb 2025 02:36 |
Last Modified: | 27 Feb 2025 02:36 |
URI: | http://repository.univawalbros.ac.id/id/eprint/342 |