PERBANDINGAN KUALITAS CITRA MENGGUNAKAN COMPUTED RADIOGRAPHY (CR) DAN DIGITAL RADIOGRAPHY (DR) PADA PEMERIKSAAN CRANIUM PROYEKSI ANTERO - POSTERIOR (AP)

Saputra, Wahyu (2024) PERBANDINGAN KUALITAS CITRA MENGGUNAKAN COMPUTED RADIOGRAPHY (CR) DAN DIGITAL RADIOGRAPHY (DR) PADA PEMERIKSAAN CRANIUM PROYEKSI ANTERO - POSTERIOR (AP). D3 Teknik Radiologi thesis, Universitas Awal Bros.

[img] Text
KTI_WAHYU SAPUTRA_21002047.pdf

Download (2MB)
[img] Text
BAB1_WAHYU SAPUTRA.pdf

Download (205kB)
[img] Text
DAFTARPUSTAKA_WAHYU SAPUTRA.pdf

Download (309kB)

Abstract

abtrak Computed radiography (CR) merupakan teknik pencitraan radiografi yang menggubah sistem analog menjadi digital menggunakan photo stimulable phospor (PSP), Digital radiography (DR) merupakan jenis sistem pencitraan digital kedua yang menggunakan detektor flat panel dengan thin-film transistor (FPD-TFT) yang telah terpasang pada kaset. Kelebihan CR dan DR lebih mudah digunakan dan waktu pemeriksaan menjadi singkat, faktor eksposi yang digunakan bisa diturunkan dari faktor eksposi standar yang telah ditentukan, faktor eksposi adalah faktor yang mempengaruhi kualitas citra radiograf. Tujuan dari penelitian ini untuk melihat bagaiman perbedaan kualitas citra radiograf dengan menggunakan CR dan DR pada pemeriksaan Cranium ap dengan menurunkan Faktor eksposi sebanyak 15% dengan menggunakan perhitungan SNR. Jenis penelitian yang digunakan pada penelitian Karya Tulis Ilmiah ini yaitu bersifat kuantitatif deskriftif dengan metode eksperimen. Dengan menggunakan uji wilcoxon dan perhitungan SNR. Penelitian ini dilakukan di Laboratorium Universital Awal Bros Hasil kesimpulan pada penelitian ini didapatkan bahwa ada perbedaan antara CR dan DR, dengan p value = 0,028 < 0,05 yang artinya terdapat perbedaan terhadap hasil Citra menggunakan CR dan DR. Kualitas citra SNR yang bagus terdapat pada DR dengan nilai 76.76 . Kata kunci : CR, DR,Cranium, kualitas citra, SNR ABSTRACK Computed radiography (CR) is a radiographic imaging technique that converts an analog system into digital using a photo stimulable phosphor (PSP), Digital radiography (DR) is a second type of digital imaging system that uses a flat panel detector with a thin-film transistor (FPD-TFT) which installed on the cassette. The advantages of CR and DR are that they are easier to use and the examination time is shorter, the exposure factor used can be derived from a predetermined standard exposure factor, the exposure factor is a factor that influences the quality of the radiograph image. The aim of this study was to see the difference in radiograph image quality using CR and DR in AP Cranium examination by reducing the exposure factor by 15% using SNR calculations. The type of research used in this scientific paper research is quantitative descriptive with experimental methods. Using the Wilcoxon test and SNR calculation. This research was conducted at the Awal Bros University Laboratory from April-May 2024 The conclusion of this research is that there is a difference between CR and DR, with p valeu = 0.028 < 0.05, which means there is a difference in image results using CR and DR. Good SNR image quality is found in DR with a value of 76,76 Keywords: CR, DR,Cranium, image quality, SNR

Item Type: Thesis (D3 Teknik Radiologi)
Subjects: D3 Radiologi > X-Ray Konvensional
Divisions: Fakultas Ilmu Kesehatan > D3 Radiologi
Depositing User: WAHYU SAPUTRA RAD
Date Deposited: 27 Feb 2025 02:36
Last Modified: 27 Feb 2025 02:36
URI: http://repository.univawalbros.ac.id/id/eprint/316

Actions (login required)

View Item View Item